Welcome to Fink International Trading (Hongkong) Co., Ltd.!

Dual-Channel Conductivity Analyzer


Description:
Model CodeFLXA21FLXA202DC402G
Area Classification
  • General Purpose

  • Class I Div II (without the use of IS Barrier)

  • Class I Div I (with the use of IS Barrier)

  • General Purpose

  • Class I Div II (without the use of IS Barrier)*FM/CSA Pending

  • Class I Div I (with the use of IS Barrier)*FM/CSA Pending

  • General Purpose

  • Class I Div II

Enclosure MaterialPlastic (Polycarbonate)Aluminum alloy die cast with epoxy coating (Standard offering)
Aluminum alloy die cast with urethane or high anti corrosion coating (available upon request)
Cast Aluminum with chemically resistance coating; polycarbonate cover with polycarbonate flexible window
Housing RatingIP66/ NEMA 4A/ CSA 3SIP66 (except Canada), Type 4X (except Canada), Type 3S/4X (Canada)IP66/ NEMA 4A/ CSA 3S
Power Supply2-wire 24VDC, Loop Powered2-wire 24VDC, Loop Powered4-Wire 110-256 VAC, Mains Power
Output SignalBi-directional HART digital communication, superimposed on mA (4-20mA) signal.Bi-directional HART digital communication, superimposed on mA (4-20mA) signal.Two isolated outputs of 4 to 20 mA DC with common negative.

The model FLEXA® two-wire analyzer is used for continuous on-line measurements in industrial installations. It offers an option for single or dual sensor measurement, making it the most flexible 2-wire analyzer available. The model FLEXA® modular-designed series analyzer.

  • One analyzer can accept any of 4 types of measurements; pH/ORP, Contacting Conductivity (SC), Inductive Conductivity (ISC) and Dissolved Oxygen (DO)

  • Dual sensor measurement on a 2-wire type analyzer pH/ORP and pH/ORP, SC and SC, and DO and DO

  • Modular design: replaceable sensor modules

  • Redundant system on dual sensor measurement

  • Variety of materials of construction: SS or Plastic

  • Intuitive easy touch screen operation on 2-wire type analyzer

  • Unique HMI menu structure in 12 languages

  • Quick setup menu for fast and east measurement operation

  • Online Sensor Wellness checking for predictive maintenance

  • NEMA 4X / IP66 Enclosure

Flexibility, reliability and low maintenance are among the benefits provided by the EXA DC402G conductivity analyzer. Designed to meet the exacting requirements of measuring dual cell conductivity and resistivity in the modern industrial environment, it contains many features to ensure the best precision whatever the application. Differential, ratio, deviation. % passage or % rejection can be indicated and/or transmitted. 

This 4-wire converter is housed in a robust IP65 field mountable case. Two mA outputs, four relays, digital communication and a clear LCD make the DC402G a truly comprehensive package. 

The DC402G features PI control on the auxilliary mA output and the pulse proportional relay outputs, thus avoiding the need for a separate controller.

The famous EXA sensor diagnostics are also present in the DC402G. Self-tuning of the excitation frequency and measuring pulses ensure optimum accuracy. The polarisation check gives on line indication of sensor fouling and early warning that maintenance is needed. A wide variety of temperature compensation possibilities (NaCl according to IEC 746-3, manual TC, preprogrammed matrices and a freely programmable 5x5 matrix), provides a high-accuracy measurement with minimum effort.

  • Differential, ratio or calculated outputs

  • Universal conductivity/resistivity, software switchable

  • On-line sensor checking

  • Self-tuning measuring signal

  • Matrix temperature compensation for pure water applications

  • Four fully configurable SPDT contact outputs

  • Two fully configurable mA outputs

  • Built-in PI controller

  • Easy to use EXA control panel

  • USP 23 monitoring


Looking for more information on our people, technology and solutions?

Browse:
Return To The Top

分享到: