Modular GM10

Industrial processes often employ multiple data acquisition systems to monitor the health of assets and facility infrastructure. These systems can be either standalone or built as nodes within a larger automation topology.

The GM10 is a scalable modular block I/O data acquisition system and data-logging platform that is designed for easy installation and maintenance and requires no programming.  It supports remote web-based or wireless configuration and monitoring via Bluetooth connection. The unit can be DIN rail mounted, wall mounted or act as a standalone desktop application. The Yokogawa GM10 delivers industry leading reliability and measurement accuracy. In addition, a wide range of communication protocols guarantee compatibility with your network architecture.



Description:

Industrial processes often employ multiple data acquisition systems to monitor the health of assets and facility infrastructure. These systems can be either standalone or built as nodes within a larger automation topology.

The GM10 is a scalable modular block I/O data acquisition system and data-logging platform that is designed for easy installation and maintenance and requires no programming.  It supports remote web-based or wireless configuration and monitoring via Bluetooth connection. The unit can be DIN rail mounted, wall mounted or act as a standalone desktop application. The Yokogawa GM10 delivers industry leading reliability and measurement accuracy. In addition, a wide range of communication protocols guarantee compatibility with your network architecture.

Main Features

Scalability

  • Up to 420 ch per system

  • Plug and lock modules

Ease of Use

  • Web-based configuration

  • Live Web-based data viewing

Mobile Connectivity

  • Bluetooth

  • Mobile Application

Reliability

  • Secure data storage

  • High accuracy measurement

  • Automatic backfill function (GA10 Data Logging Software)

Noise Tolerance

  • Electromagnetic relay module

21 CFR Part 11 support (option)

  • Supports the U.S. FDA 21 CFR Part 11 (for pharmaceutical manufacturing).

Wide-ranging input/output specifications

  • The 10 channel universal input module measures DC volts, thermocouple, RTD, and contact input signals. A 16 channel digital input module and a relay output module are also available.            

    • GX90XA Analog Input Module: DC voltage, thermocouple, RTD, contact, DC current

    • GX90YA Analog Output Module: New! Retransmission output of input/math/communication channels, manual output

    • GX90XD Digital Input Module: Remote control input, pulse input

    • GX90YD Digital Output Module: Alarms and other output

    • GX90WD Digital Input/Output Module: Remote control input, alarm output, pulse input

    • GX90XP Pulse Intput Module:[R3]New! Pulse signal data acquisition, integral count

Supports 12 to 28 VDC power [R3] New!

  • Supports 12 to 28 VDC power so you can also use it inside automobiles.

Multi-batch Function (option) [R3] New!

  • Recorder pre-defined channel groups to separate data files with independent start and stop control.

SLMP Communication (Mitsubishi PLC) (option) [R3] New!

  • Protocol function that enables connection from a GM to Mitsubishi Electric PLCs without sequence programs.

OPC-UA Server (option) [R3] New!

  • Data acquired by the GM can be accessed through Ethernet communication from a host system (OPC-UA client).

Aerospace Heat Treatment Supports heat treatment application AMS2750/NADCAP [R3] New!
Calibration correction schedule control function (option)

  • Schedule management for periodically executing calibration correction configuration and the like.

Enables a scalable data acquisition system

Increase channels by adding additional block modules

YOKOGAWA proprietary block architecture (patent pending)

  • Expand one, or multiple module at a time

  • Unique design houses modules in linked module bases

  • Module base ensures linkage (slide locks and mounting screws also available)

  • Modules can be inserted and removed from the front panel for easy maintenance

Gm Image02

Names of data acquisition module parts

Gm Image01

Comes standard with support for up to 100 ch of measurement (single-unit configuration)

Up to 10 I/O modules can be linked to a single data acquisition module (GM10)

Gm Image03

Installs anywhere

For the desktop, DIN rails, or wall-mounting. No special attachments required.

Gm Image04

 

Select from a wide range of I/O modules

Gm Image05Select modules according to your application. Noise-resistant, magnetic relay types also available. All modules have removable terminal blocks for easy wiring. The same modules used in the SMARTDAC+ series.

ModelNameMeasurement/ApplicationChannels
GX90XA-10-U2Analog input moduleDC voltage, thermocouple, RTD, contact (semiconductor relay scanner type)10
GX90XA-10-L1DC voltage, thermocouple, contact (low withstand voltage)10
GX90XA-10-T1DC voltage, thermocouple, contact (electromagnetic relay scanner type)10
GX90XA-10-C1DC current (mA)10
GX90XDDigital input moduleRemote control input, operation recording, or pulse input16
GX90YDDigital output moduleAlarm output 6
GX90WDDigital input/output moduleRemote control input, operation recording or pulse input/alarm outputDI:8/DO:6
GX90XPPulse input modulePulse input module up to 20kHz10

Analog input module scan interval and measurement type

TypeChannelsScan interval
(shortest)
ScannerTCRTDDCVDImAUse
Universal (-U2)10100msSSR √ √ √ √
Universal
Low withstand voltage relay(-L1)10500msSSR √
 √ √
Mid-price
Electromagnetic relay
(-T1)
101sRelay √
 √ √
Noise-
resistance
DC current input (-C1)10100msSSR



 √mA only

Internal memory and max. I/O channels

TypeInternal memoryMax. input/output channels
GM10-1500 MBSingle-unit configuration0 to 100
Multi-unit configuration0 to 100
GM10-21.2 GBSingle-unit configuration0 to 100
Multi-unit configuration0 to 420

Actual values support high precision measurement

Input typeMeasuring accuracy* (typical value)
DCV20 mV±(0.01% of reading + 5µV)
6 V (1-5V)±(0.01% of reading + 2mV)
TCR±1.1 °C
K (-200 to 500 °C)±0.2 °C However, -200.0 to 0.0°C: ±(0.15% of reading + 0.2 °C)
T±0.2 °C However, -200.0 to 0.0°C: ±(0.10% of reading + 0.2 °C)
RTDPt100±(0.02% of reading + 0.2 °C)
Pt100 (high resolution)±(0.02% of reading + 0.16 °C)

The measuring accuracies noted in the general specifications have a margin of error that takes into account the product's components and the equipment used for adjustment and testing. However, the actual values calculated from the accuracy testing data upon shipment of the instrument from the factory are listed to the left.
* General operating conditions: 23±2 °C, 55±10% RH, supply voltage 90-132, 180-264 VAC, supply frequency within 50/60 Hz ±1%, warm-up of 30 minutes or more, no vibrations or other hindrances to performance.

Supports measurement of up to 420 ch (actual input) by expanding channels across multiple units (multi-unit configuration)

Expand up to 420 ch by using the GX90EX expansion module. (GM10-2) On the GM10-2 large capacity type, up to 1000 ch are available for recording when including MATH and communication channels. Connect units with Ethernet cables for dispersed installations.
Gm Image10

Reduce wiring with distributed installation

When the data logger is installed offsite (away from the DUT), you can place the sub unit at the site and monitor data without the need for long-distance wiring of thermocouples and other sensors.

Gm Image11

as of March, 2017

The SD cards of the following manufacturers have been verified for use with SMARTDAC+® GX/GP/GM, µR10000™/µR20000™ and FX1000™. However, please note that Yokogawa does not guarantee normal operation of the SD card when using with products listed below.

SMARTDAC+ GX
Applicable Models: GX10, GX20, GX20W
SMARTDAC+ GP
Applicable Models: GP10, GP20
SMARTDAC+ GM
Applicable Models: GM10

√: Verified
ManufacturerCapacityManufacturer ModelGX10GX20GP10GP20GX20WGM10
SanDisk16GBSDSDXS-016G
SanDisk  8GBSDSDXS-008G
SanDisk32GBSDSDXVE-032G
SanDisk32GBSDSDXS-032G
SanDisk32GBSDSDXL-032G
SanDisk16GBSDSDXL-016G
SanDisk  8GBSDSDXL-008G

Applicable Models: µR10000/EM1, µR20000/EM1 

√: Verified
ManufacturerCapacityManufacturer ModelµR10000/EM1µR20000/EM1
SanDisk32GBSDSDXVE-032G
SanDisk32GBSDSDXS-032G

Applicable Models: FX1000

√: Verified
ManufacturerCapacityManufacturer ModelFX1000
SanDisk32GBSDSDXVE-032G
SanDisk32GBSDSDXS-032G

In rare cases, the SD card is not recognized or generates an error when inserted into the instrument. If this occurrs, try the following.

  • Eject the SD card, then reinsert it.

  • Replace with a SD card that you know to be working normally.

  • Format the SD card on the Products (all data on the card will be deleted).

Please direct inquiries regarding the other manufacturers' verified SD cards above to their manufacturers.
Please note that sales of the above-mentioned SD card may be discontinued from the manufacturer without prior notice.


Looking for more information on our people, technology and solutions?

Browse:
On A:Standalone MW100
Next:No
Return To The Top

分享到: